Compensations
If you use several fluorochromes (for example A and B) in a single experiment, the emission spectra may overlapped. Thus, it is necessary to compensate the signals, that is to say to eliminate the fluorescence provided by the A fluorochrome in the channel where you read the B fluorescence.
To well set up the compensations, you need mono-staining of each used fluorochrome in the experiment.
Please, contact the manager of the facility to optimize your fluorochrome choices regarding the cytometer installed on the facility.
Confocal Leica SP8
multidimensional scan mode
3D imaging on fixed or live cell sample
suitable for F-techniques (FRAP - FRET)
20X HC Plan Apochromat 0.7 NA CS
40X HCX corr Plan Apochromat CS 1.1 NA water
40X HCX Plan Apochromat CS 1.3 NA oil
63X HCX Plan Apochromat CS 1.4 NA oil
Lasers : 405, Argon (458, 488, 514), 561, 633
Filters cubes
DAPI (Ex BP340-380, Em LP425
FITC (Ex Bp450-490, Em LP515
GFP (Ex BP480/40, Em BP527/30)
DsRed Et,k (Ex BP546/12, Em BP605/75)
spectral acquisition in confocal mode
FRAP / FRET
confocal LSM880 Airyscan
Confocal Zeiss LSM880 Airyscan
+ DIC images
Controled by Zen 2012 software
10X EC Plan Neofluar 0.3NA
20X Plan Apo 0.8NA
40X Plan Apo huile 1.3NA
63X Plan Apo huile 1.4NA
HXP120 lamp
Cubes for occular widefield visualisation: DAPI, GFP, Cy3
Excitation sources for confocal mode:
Diode 405nm
Argon LASER (458, 488, 514nm)
DSSP 561nm
Helium/Neon LASER 633nm
-2 PMT for fluorescence
-1 internal GaAsP detector
-1 PMT for transmission
-1 Airyscan detector (32 GaAsP detectors)
Environment control: temperature and CO2
Zeiss Zen Software
-multi-modal acquisition: XYZ, spectral, time, multi-positions or mosaic
-"super-resolution" imaging
-hardware auto-focus Definite Focus
-FRAP module
-3D mosaic module
Confocal ZEISS LSM880 FastAiryscan
Improvement of spatial resolution and speed with Airyscan and FastAiryscan module.
Microscope equiped with DIC and autofocus
10X/0.3 Plan-neofluar
20X/0.8 Plan-apochromat
40X/1.1 W C-apochromat (long distance) DIC
40X/1.4 Oil Plan-apochromat DIC
63X/1.4 Oil Plan-apochromat DIC
Occular fluorescence with HXP120
filter cubes : DAPI, GFP, Cy3
Diode 405
Laser Argon 458, 488, 514
DSSP 561
Laser He/Ne 633
Detectors :
- 2 PMT fluorescence
- 1 GaAsP (high sensitivity)
- 1 PMT Transmission
- 1 Airyscan detector (32 GaAsP)
Acquisition software : ZEN black (.czi files format)
- "super-resolution" imaging with Airyscan and FastAiryscan module
- hardware solution for autofocus (Definite focus)
- FRAP, FRET, Photoactivation module
- Experiment designer module
CONFOCAL ZEISS LSM980 AIRYSCAN
20X Plan Apo 0.8NA
40X Plan Apo huile 1.3NA
63X Plan Apo huile 1.4NA
40X Plan Apo eau 1.1NA
-2 PMT for fluorescence
-1 GaAsP spectral detector 32 chanels
-1 PMT for transmited light
-1 AiryScan2 detector
Colibri 5
Cube for widefield visualisation : 3 bands DAPI/GFP/CY3
Environment control: Temperature, CO2 and humidity
Excitation sources for confocal mode :
Laser diodes 405nm, 445nm, 488nm, 515nm, 561nm and 639nm
Zeiss Zen Blue Software
-multi-modal acquisition: XYZ, spectral, time, multi-positions & mosaic
-« super-resolution » imaging for fixed samples
-Live and « super-resolution » imaging with the multiplex 4Y & 8Y AiryScan
-AI Sample Finder module
-FRAP module
Confocal Zeiss LSM980 Airyscan 8Y
Controled by Zen Blue.
5X Plan Neofluar 0.16NA
10X Plan Apo 0.45NA
20X Plan Apo 0.8NA
40X Plan Apo oil 1.3NA
63X Plan Apo oil 1.4NA
Colibri 7
Cubes for ocular widefield visualisation : 3 bandes DAPI/GFP/CY3
Excitation sources for confocal mode :
Diode 405nm
Diode 488nm
Diode 561nm
Diode 639nm
-2 PMT for fluorescence
-1 internal GaAsP detector
-1 PMT for transmission
-1 Airyscan 2 detector
Environment control : no
Environment control: not available
Zeiss Zen Blue Software
-multi-modal acquisition: XYZ, spectral, time, multi-positions & mosaic
-« super-resolution » imaging for fixed samples
-Live and « super-resolution » imaging with the multiplex 4Y & 8Y AiryScan
-AI Sample Finder module
-FRAP module
Confocal Zeiss LSM980 NLO
10X EC Plan Neofluar 0.3NA
20X Plan Apo 0.8NA
40X Plan Apo oil 1.3NA
63X Plan Apo oil 1.4NA
40X C-APO water 1.4NA
HXP120 lamp
Cubes for occular widefield visualisation: DAPI, GFP, Cy3
Sources d'excitation mode confocal :
Diode 405nm
Diode 488nm
Diode 561nm
Diode 639nm
Multiphoton laser:
Chameleon Ultra-II Coherent LASER (680-1080nm)
-2 PMT fluorescence
-1 multi-PMT (32 détecteurs GaAsP) spectral detectorl
-1 PMT transmission
-1 camera for tilescan preview
-1 detector FLIM (photon counting for FLIM of GFP or Cy3)
Temperature and CO2 control
Zeiss Zen Blue Software
-multi-modal acquisition: XYZ, spectral, time, multi-positions & mosaic
-FRAP module
Software Becker Hickl SPCM et SPC-100
-module FLIM (cart and detector Becker-Hickl)
Contact us
About an order or a problem in the subscription process
Send an e-mail to à This email address is being protected from spambots. You need JavaScript enabled to view it.
To contact a specific MRI facility
As a general rule, contact the person in charge of the targeted facility, whose contact details can be found on the webpage dedicated to the facility and in the directory.
Alternatively, you can use the generic addresses of facilities with several engineers:
Send an e-mail to This email address is being protected from spambots. You need JavaScript enabled to view it. to contact MRI imaging facility located at the CRBM
Send an e-mail to This email address is being protected from spambots. You need JavaScript enabled to view it. to contact MRI imaging facility located at the IGH
Send an e-mail to This email address is being protected from spambots. You need JavaScript enabled to view it. to contact MRI imaging facility located at the INM
Send an e-mail to This email address is being protected from spambots. You need JavaScript enabled to view it. to contact MRI flow cytometry facility located at the IGMM
Send an e-mail to This email address is being protected from spambots. You need JavaScript enabled to view it. to contact MRI flow cytometry facility located at the IRMB
Send an e-mail to This email address is being protected from spambots. You need JavaScript enabled to view it. to contact MRI image analysis service MRI-CIA
For any other subject or if you don't know who to contact :
Send an e-mail to This email address is being protected from spambots. You need JavaScript enabled to view it.